| Item information | Value |
|---|---|
| GTIN: | 9120053865591 |
| Category: | Sauna Lighting |
| Country of origin: | Austria |
| Content: | 1,00 Piece |
Harvia LED Power Supply 90 W / 24 V DC – LED-PWS-24-90
Recommended Accessories
The Harvia LED-PWS-24-90 should be considered an integral component of a complete lighting system rather than an isolated electrical accessory. Its purpose is to provide the required 24 V DC electrical supply to compatible lighting equipment and control components. To achieve the desired lighting result, the power supply, LED luminaires, controllers, drivers and connection cables must be selected as a coordinated system.
For RGBW sauna lighting, compatible LED tubes are among the most relevant additional components. RGBW technology combines red, green, blue and white lighting channels, allowing different lighting colours and white illumination to be produced when connected to suitable control equipment. The power supply provides the electrical energy needed for the installation, while the appropriate controller or driver manages the lighting functions. The LED-PWS-24-90 itself does not replace a DMX controller or provide independent colour-control functions.
A compatible DMX controller and the appropriate lighting driver may be required when the installation is intended to support individual colour selection, programmed lighting sequences or integration into a more comprehensive lighting-control system. Compatibility must be checked carefully because DMX equipment can differ in its supply voltage, output configuration and electrical requirements. Components should only be connected when their specifications permit the intended combination.
Connection cables and suitable electrical connectors are equally important. They must be appropriate for the system voltage, expected current, installation environment and cable routing. Poorly selected connections can result in voltage losses, unreliable operation or electrical safety problems. Particular attention should be paid to maintaining correct polarity and avoiding unnecessary cable lengths.
When selecting lighting accessories, the combined electrical load must remain within the permitted output of the power supply. Although Harvia specifies the 90 W version for RGBW LED tube systems with a total length of up to 5 metres, this application guidance does not eliminate the need to verify the actual requirements of the connected devices. Additional controllers or other electrical consumers must also be considered when calculating the total load.
The installation environment is another important consideration. Sauna lighting systems may include components intended for areas exposed to heat or humidity, but this does not mean that every electrical component has the same environmental protection. The LED-PWS-24-90 power supply must be installed in a dry, appropriately protected location because it is not splash-water protected.
A carefully planned combination of power supply, lighting elements, control equipment and suitable cables makes installation easier and helps maintain the intended functionality of the lighting system. It also supports a neat installation in which electrical components can be positioned away from visually prominent areas while remaining accessible where required for inspection or maintenance.
Selecting compatible accessories from the beginning reduces the risk of incorrect connections, unnecessary modifications and unsuitable component combinations. This is particularly important in sauna lighting projects, where electrical requirements must be considered together with the environmental conditions of the installation.
Important Information on Installation and Use
The Harvia LED-PWS-24-90 is an electrical power supply designed for compatible 24 V DC lighting systems. Correct installation is essential to ensure safe and reliable operation. Because the unit is connected to a 230 V mains electrical supply, installation and electrical connection work must be performed by a suitably qualified electrician in accordance with the manufacturer's instructions and applicable electrical regulations.
Electrical supply and output voltage: The specified primary energy source is electricity at 230 V, 1N~, with a frequency of 50/60 Hz. The output voltage is 24 V DC, and the maximum specified power is 90 W. Before connecting any equipment, the installer must confirm that the connected lighting components or controllers are designed for the supplied output voltage and that their combined power consumption does not exceed the permitted capacity.
The distinction between the mains input and the low-voltage DC output is particularly important. Equipment intended for a different voltage must not be connected directly to the 24 V DC output. Incorrect voltage selection can damage connected components or create electrical hazards.
Dry installation location: The power supply must be installed in a dry location. It is not protected against splashing water and must therefore not be positioned where it may be exposed to water droplets, direct splashing, condensation or unsuitable levels of moisture. This requirement is especially important when planning electrical installations for sauna rooms and surrounding wellness areas.
The power supply should not be installed directly in a wet area or in a location exposed to excessive heat unless the manufacturer explicitly permits that installation arrangement. The actual installation location must comply with the applicable environmental limits and all requirements stated in the product documentation.
Mounting and positioning: Before installation, sufficient space must be available for the unit and its electrical connections. The device measures approximately 145 mm in depth, 59 mm in width and 32 mm in height. These dimensions assist with installation planning but do not replace any required mounting clearances stated by the manufacturer.
The unit should be mounted securely in accordance with the manufacturer's instructions. Cable connections must not be subjected to excessive mechanical stress, and the installation should allow appropriate access for inspection or servicing where required.
Power calculation: The maximum output rating of 90 W must be considered when designing the lighting system. The total connected load should be calculated using the specified power consumption of the lighting fixtures and any additional components powered by the unit. The system must not be operated beyond the manufacturer's permitted output rating.
For Harvia RGBW LED tubes, the manufacturer identifies the 90 W power supply as suitable for installations with a total tube length of up to 5 metres. This recommendation applies to the corresponding compatible lighting equipment. Other LED products may have different power requirements and must be evaluated individually.
DMX lighting integration: When used with DMX-controlled lighting, the power supply must be connected according to the specifications of the relevant controller and driver. A DMX controller controls lighting functions, while the power supply provides electrical energy. These functions should not be confused during installation.
The installer must verify that the selected DMX controller and lighting driver are electrically compatible with the 24 V DC supply. The necessary connection arrangement depends on the equipment used and must follow the appropriate manufacturer documentation.
Electrical connections: All connection and installation work must be carried out with the electrical supply disconnected. Correct polarity, secure terminals and appropriate cable specifications are essential. The supplied connection cable must be used only for its intended purpose and in accordance with the manufacturer's instructions.
Additional cables and connectors must be selected to suit the expected electrical load and the installation environment. Connections must be protected from accidental damage, excessive mechanical tension and unsuitable environmental conditions.
Initial commissioning: Before the power supply is switched on for the first time, the complete installation should be checked. The installer should verify the mains connection, output wiring, polarity, connected load and compatibility of all lighting and control components.
After commissioning, the lighting system should be tested to confirm that the connected equipment operates as intended. Where DMX control is used, the controller and driver should be checked separately to ensure that the required lighting functions respond correctly.
Operation and maintenance: The power supply should be used only for its intended electrical application. It must not be exposed to water or operated in conditions that do not comply with the manufacturer's requirements.
If unusual operating behaviour, visible damage, overheating or other signs of a malfunction occur, the system should be disconnected from the electrical supply and inspected by a qualified specialist. The power supply must not be opened or modified by unauthorised persons.
The manufacturer's current installation and operating documentation must always be consulted before installation. Technical values, environmental limitations and connection requirements stated in that documentation take precedence over general installation recommendations.
A correctly installed Harvia LED-PWS-24-90 contributes to a well-coordinated sauna lighting system by providing the required 24 V DC supply within its specified power limits. Careful planning of the installation environment and connected equipment is essential for reliable long-term operation.
Why Buy From Us?
As a partner of the Harvia brand, we understand the importance of selecting compatible components for professional and private sauna installations. A successful sauna lighting project requires more than individual products. Every electrical component must fulfil a specific function within the complete lighting system.
At Amilano, we focus on offering coordinated sauna equipment and accessories that allow customers to plan their installations with greater confidence. Our product range includes lighting solutions, control technology and other sauna components, helping customers identify suitable products for their individual projects.
Choosing the correct power supply is particularly important when installing RGBW lighting or DMX-controlled systems. Different lighting arrangements have different voltage and power requirements. Selecting an unsuitable power supply can create unnecessary installation difficulties, additional costs or compatibility problems.
We help customers understand the differences between available product versions and the technical considerations involved in choosing suitable equipment. With the Harvia LED-PWS-24-90, important factors include the 24 V DC output voltage, the 90 W maximum power rating, compatibility with the intended lighting components and the requirement for installation in a dry location.
Our approach is based on understanding how individual components work together. Power supplies, LED lighting elements, DMX controllers, drivers and connection accessories must be considered as parts of one installation rather than unrelated products.
This system-oriented approach is especially valuable for customised sauna projects, where lighting is integrated into benches, wall elements, architectural details or other carefully designed areas. Properly selected electrical components make it easier to create an installation that combines practical lighting requirements with the intended visual appearance.
We also recognise that technical product information must be clear and understandable. Correct specifications and compatibility information are essential for both professional installers and private customers planning their sauna lighting systems.
By combining the established Harvia product range with our experience in sauna equipment and accessories, we aim to help customers avoid incorrect product combinations and make informed purchasing decisions.
Whether you are planning a new sauna installation, upgrading an existing lighting system or replacing a compatible power supply, Amilano offers a practical point of contact for selecting the appropriate components.
Choose Amilano for a carefully selected sauna product range, an understanding of technical compatibility and a purchasing experience focused on finding the right solution for your individual requirements.
Warranty & Conditions
The Harvia LED-PWS-24-90 is manufactured for use as an electrical power supply in compatible lighting installations. Any applicable manufacturer's warranty is governed by the official Harvia warranty conditions for the relevant product and market.
Harvia's published warranty information addresses protection against qualifying material and manufacturing defects. The applicable warranty period, scope of coverage and any exclusions must be determined from the current official warranty conditions for this particular product.
Warranty duration: The exact manufacturer's warranty duration for the LED-PWS-24-90 must be verified against the applicable Harvia documentation. No additional warranty period beyond the manufacturer's confirmed terms is promised in this product description.
Private and commercial use: Warranty conditions may depend on the intended application and the applicable manufacturer terms. Customers planning commercial installations should verify whether different warranty provisions or installation requirements apply.
Installation requirements: The power supply must be installed in accordance with the manufacturer's instructions and applicable electrical safety regulations. The electrical connections must be suitable for the specified 230 V mains supply and 24 V DC output.
The installation location must meet the manufacturer's environmental requirements. In particular, this power supply is not protected against splashing water and must be installed in a dry, appropriately protected location.
Correct operation: The connected electrical load must remain within the permitted output capacity of the power supply. Only compatible electrical components should be connected, and the equipment must be operated according to its intended purpose.
Warranty exclusions: Damage resulting from incorrect electrical connections, unsuitable installation conditions, excessive electrical loading, unauthorised modifications or operation contrary to the manufacturer's instructions may fall outside the applicable warranty coverage. The precise exclusions are defined by the official warranty terms.
Proof of purchase: Customers should retain their purchase invoice and any relevant installation documentation. These records can help establish the purchase date, identify the product and support the processing of a warranty claim.
When reporting a potential defect, it is advisable to provide the model designation LED-PWS-24-90, a description of the problem and relevant information about the connected lighting equipment and installation conditions.
Statutory rights: Any applicable statutory rights against the seller remain unaffected by a separate voluntary manufacturer's warranty. Statutory rights and manufacturer warranty coverage are distinct and may be subject to different legal conditions.
For definitive information about warranty duration, coverage, exclusions and claim procedures, the current official Harvia warranty documentation should be consulted.
Following the manufacturer's electrical, installation and operating requirements is essential for safe use and helps protect the equipment against avoidable damage.
Harvia GmbH, Wartenburger Straße 31, 4840 Vöcklabruck, Burgenland, Österreich, info@harvia.com